and I have had no issues with leaks or sewer gas. Great job! To help narrow it down you may want to add some food coloring to your bowl water. I have a Gerberit wall mounted carrier ( https://www.geberitnorthamerica.com/products/installation-systems/system-for-floor-mount-toilets/index.html) with a Nameek floor mounted toilet (http://www.nameeks.com/product/Toilet/Scarabeo-5522.html). I’m trying to convert a 1/2 bath to a full bath. I was originally going to have to use three 90’s to get the waste from the toilet to the soil stub up. Z5615-BWL, Z6516-BWL, Z5617-BWL EcoVantage® HET Wall Hung Toilet System. The cistern often also disappears behind the installation … I’m very greatfull you posted this project in such detail & extremely well isustrated too. The tank is in the wall, only the toilet itself is hung on the wall. I’m sure you are working on it – let us know what you do. See page 9 of the installation instructions – here is the link: Gerebit Wall Hung Toilet Install Instrutions, Your post is excellent, thank you. https://www.pinterest.com/redwoodbluepine. I added this whole bathroom to my remodel. With a concealed tank, minimal footprint and installation flexibility, a wall-hung toilet in the home can save up to 12 inches of space over our longest floor-mount models. 15 plumbers ran away when I showed them the tank. There are all kinds of questions about getting the right plumber, expense etc. Only to find out later these expensive home application in-wall-tank carriers are just that “home application.” No one uses these commercially for reasons I already mentioned. So thorough and detailed. Once the connection is complete, protect the plumbing connection opening by capping them with the supplied yellow plaster caps. Geberit told me on Dec. 4, that they were too busy to come to the house and would come after Christmas. I think that by giving your 3″ -> 3 1/8″ example, your web site gives by far the clearest info on this issue and the one applicable for any brand of wall mount toilet. To me it sounds like your downstairs unit is connected to drain plumbing with inadequate venting or improper drain plumbing connections or even leaks. It also has an advantage of height adjustment as per the user preference. Our downstairs smells like a disgusting sewer if the toliets go unused for a few weeks. There are some preparation that must be done to the wall before you can mount the wall hung toilet. Got a great price on the tank from PoshHaus with free two-day delivery and toilet, seat and actuator from Supply.com. Despite the concerns, the Geberit in-wall tanks have been very popular in Europe for decades and popular with commercial installs, which gives some piece of mind regarding reliability. If you haven’t installed the tank yet, you could fill it and check for leaks before putting it in your wall. Test the flushing function by pushing on each control rod – it should initiate a flush cycle. Gary, Thank you so much for your response. Step 4. We have had nothing but high praise for it and after several years of use, never once had a issue or clog. It is concerning to hear about the indifference of the customer service department though. Attach the tank, if it is not already pre-installed onto the frame. The tank does allow easy access to the flushing components via the front activation panel. I am not concerned with freezing as I live in Florida. Mark the bolt hole locations at the base of the unit as well. The Inspector was not very familiar with wall mount toilets, but seemed happy with my work and gave me a pass for the plumbing rough in. Perhaps too much involved in moving the current waste plumbing? Hmmm… tough situation. It helped me tremendously with the prep-work for the unit. Is it a valid concern? Recheck the measurements and make sure it is all ready for the installation. (image from Geberit – used with permission). Switch to the dark mode that's kinder on your eyes at night time. Especially the suggestion doubling up the 2x4s (although likely not necessary) but there Is absolutely no movement. Install the splash guard first by inserting the lower tabs then swinging the top in until the top tabs lock. The extra, Ledge wall is needed to hold the flush tank inside. My question: Since I don’t need the carrier for the in-wall tank, is it ok to just beaf up my wall with pressure treated wood and mount the toilet on that? As long as the toilet in and out openings match the Geberit’s carrier plumbing the system will work. If using lag bolts be sure to drill the proper size hole into the wood framing prior to installing the bolts. The kit is available for both a 3 and 4 inch (90mm and 110mm) waste exit on the toilet. Much of that depends on the framing you have in your wall. Geberit supplied protective plaster caps. More Buying Choices $303.15 (6 new offers) Geberit 111.798.00.1 Concealed Toilet Carrier Frame with Dual-Flush Tank for 2 x 4" Walls. Or what height is the top of the pan without the toilet seat? The only other issue I’ve had is with the volume of water related to the half flush function on the Geberit. Other causes of the sewer smell are plumbing leaks behind the wall or under the slab. This cotton white modern fixture is an incredible addition to the bathroom having elongated seat and wall-mounted installation. It is considered to be a great addition to the small bathrooms. Vivian. You know that disgusting spot behind the toilet that you can never really reach, so it never really gets clean? Use the proper size drill for the fasteners you are using (check the installation documents). With the actuator control rods assembled, locked and working properly, finish the actuator assembly by installing the actuator cover. The other option is to consider the Generit Monolith system that mounts to the front of the wall instead of in the wall. All instructions mention cutting additional 3mm (1/8″), but some give wrong impression that the final length of the inlet and discharge pipes should be 3mm longer than exact measured and calculated length. $334.78 $ 334. I’m not sure why the plumbers you have talked to don’t seem to like wall mounted toilets – we absolutely love ours and have had no problems. I would also consider any work or changes that may have caused a leak – recent wall work, screws, etc. Since the bathroom had already been framed when we bought the house (we’re the second owners), we decided not to spend the money of running a second soil line from the second floor, through the first floor, to the craw space under the house. See Installation step #9 in the article above and watch the video. However, they provided very poor information on how to install the external trap to connect to the waste outlet. The Distance To Set The Toilet Flange From The Back Wall. When a wall-mounted toilet leaks when flushed, it means the plumbing works were not well done or the toilet seal is not sealing anymore. I did not specifically test the unit prior to closing the wall, but I did leave the access behind the unit open to check for leaks after install. The manufacturer specifically recommended this carrier. Is there any way to lower the toilet without moving the actuator ? The mounting bolts provided with our tank frame were a very loose fit in the threads of the frame. EAGO WD333 Square Modern White Ceramic Wall Mounted Toilet is the latest edition of the company that serves the purpose of the best wall mounted toilet in every possible way. What a great site! The installation -: Installation of a wall mounted WC becomes extra work since another thicker wall called the Ledge Wall is required to install this WC. If you have access to both sides of the studs, using bolts may provide a stronger mount. You could start with finding a local showroom and asking if they could recommend any plumbers who use the products. FREE Shipping. Thanks for the question and thanks for visiting the site. You might need a different plumber to look at it. Did you leave an access panel on the rear of the tank? Remember to tighten these connections only as they rely on a relatively small o-ring to seal. Not only is it the best toilet we have ever had (It has never clogged in two years of use — in fact, we have never had to use a plunger on it! After both fittings are fully engaged with the toilet bowl, mark both connector pipes at the level of the base of the back of the toilet bowl using a straight edge and marker. In other words, this type of toilet usually looks like it’s hanging from the wall, making it very different from traditional toilets. Do not use a wrench on these connections! I have a Durait toilet connected to the Gerberit tank. Ceramics and seat blend into a harmonious, elegant unit. Right now, I do not have a photo for the toilet. I’m definitely going with the Gerberit tank but having difficulty deciding on the bowl. I had to cut out a section of drywall and replace it with plywood to provide solid bridging between the bottom of the bowl and the metal tank frame. (image from Geberit), Carefully cut the supplied plumbing connections. I usually dismiss the majority of Amazon reviews as being inaccurate and biased. Many also offer tank frames for either 2×4 or 2×6 construction. 2 – TOTO Aquia Wall-Hung Dual-Flush Bowl Toilet. I would call the Geberit hotline at 1800 GEBERIT (1800 4323 748) with your question. The frame should fit snugly in the wall cavity with the sides of the frame touching the bordering studs. The legs and hardware where sold as an add-on with the sink and also from Duravit. I bought this floor mounted toilet, http://www.qualitybath.com/691311-nameeks-traccia-floor-mount-ceramic-toilet-product-187903.htm. Is his criticism of the Geberit tank accurate? The installing plumber is probably not the most objective person to help figure the problem out. Thank you for all the great information! And they use waxless insert seals like the Ferco ones, which are 10x easier to use and never fail. Thank you very much for your prompt response and for the nice words or encouragement. For your future plumbing, you will need a 1/2″ cold water supply line to the unit and a 3″ waste line below the unit. The tank is plastic and could easily be punctured at the back or front of the unit. Thank you, really, for taking the time to put this together. I had a city inspector review my plan diagram. Do you know anything about the Gerberit toilet bowls? We are building a new home at the Jersey Shore and had the architect draw in wall mounted toliets. A big plus if you think your old toilet is too short. If you do an internet search for Geberit 366.914.16.1, you should find the part. With the wall finished, the next job is to connect the toilet bowl to the wall and plumbing. My setup is very similar to yours. The wall mounted toilet pan needs to be used in conjunction with a in-wall cistern and a flush button panel on the wall. EASY TO CLEAN A wall-hung toilet makes it simple to clean beneath the bowl, and its smooth surfaces make it easy to wipe down. Wall-mounted toilets ensure that neither the flushing pipe nor the supply pipe can be seen from the outside. The manual that came with the tank doesn’t make any mention of this however I just wanted to check with your install experience. ME by Starck. We had holes showing too and I had to have the work corrected by another plumber. If the drips are colored, you could assume a bowl leak – either a seal or the bowl itself could be cracked. I’m not sure what is the space/studs in that wall between the two bathrooms? Even so, all the info I can find seems to indicate that the pipe needs to be fastened to the Geberit frame. A short section of 3″ PVC was passed from this tee through the floor plate leaving a few inches of pipe directly under the framing unit to connect the discharge plumbing from the toilet bowl. A leaking Wall-Mounted Toilet. Rough-in for a wall-hung toilet, which requires more wall cavity space to house the carrier system. There was no mention of this in the installation manual or any manufacturer videos I found. Here is a diagram: The good news is you will likely love your wall-mounted toilet – I have nothing but praise for the system after using it for 7 years! When I called the company, they were completely accomodating and helpful. Thank You, Roger. Requirements and style vary from person to person. We can attach a 4 inch piece of PVC pipe, but unsure how to secure the trap to the pipe. More Buying Choices $303.15 (6 new offers) Geberit 111.798.00.1 Concealed Toilet Carrier Frame with Dual-Flush Tank for 2 x 4" Walls. Thanks for the tips. Thanks Steve for sharing your beautiful project and the kind words. Nothing jerry rigged or “homemade” about it and the pressure tank is standard as well because few buildings have 20+ GPM. Appreciate this board, Gary, which influenced our decision to go with the tank and toilet combo. Hello, thank you for sharing all this wonderful info. Contact a supplier or the parent company directly to get a quote or to find out a price or your closest point of sale. Following the installation instructions, I measured and cut the water inlet and waste outlet pipes. Hi Maryanne, Sorry to hear about your trouble with the Geberit unit. 14 5/8" x 21 1/4" Inch . My former conventional Toto toilet needed a plunger about 1/3 of the time but this in-wall and wall-hung combination has been 100% effective in getting the job done. Here is an image (sorry, not a very good picture). Improper drain plumbing can siphon drain traps dry, even (as sometimes especially) those drain traps not being used. The most difficult aspect of wall mounted toilet installation is accommodating 3″ waste pipes. When looking for a suitable plumber, it might help to contact Geberit directly. Just because the house is new, doesn’t mean the work was done correctly or there isn’t a leak. Purchase Seat SKU: 610200001001300 separately. A rear-mounted toilet sits on the bathroom floor like a standard toilet, but instead of flushing the waste through the floor, it flushes backward through the wall behind it. It is a potentially huge problem if it doesn’t get fixed, and will potentially require ripping walls/ceilings apart later if its not remedied now. Let’s go through the steps that would make the installation of wall mounted toilet easy. Thanks for the excellent points regarding tank protection. Thanks for your response and insight.I didnt’ get a notification on your reply so sorry for the late follow-up. Prior to connecting the line, take a moment to apply a bit of o-ring lubricant to the seals prior to tightening. I chose the soft-closing Toto SS204 toilet seat with cover which I highly recommend. You might also search for commercial plumbers as they tend to install wall mounted toilets more often then residential plumbers would. Thanks for the question and thanks for using our site. I will be at the cabin this weekend and will measure the height and update this thread. Not sure what step to take next as the builders want to talk me out of these toliets. I ended up installing the Kohler K6284 carrier and K6299 toilet. It’s a special pipe- it’s not your standard 1.5 or 2 inch pipe. To measure the fittings correctly, follow the instructions provided by the in-wall unit you are using. No idea what could be the problem. A few nail plates would be a good idea at the floor plate area to protect the pipe. With toilet bowl level tighten mounting nuts. Wow Mathew! (image from Geberit – used with permission). The supply water connectors are made in a similar fashion using the supplied (white) inlet connection fitting. The builder of my home stubbed a single soil and supply lines to the second floor (see picture). This has been infinitely valuable in assisting me with my installation. It would be hard for me to say enough about the Geberit / Toto wall mounted toilet system we installed. Also, the access to the shut off valve is not easy to get to (I have a Toto system). Thank you very much for finding time and energy to document your projects. One issue I had to contend with was that, despite using 2×6 framing in the wall, I had to bore a 3.5″ hole in the doubled up stud framing on the left side of the toilet frame (facing the toilet) to accommodate the waste line. I would hire a third party plumbing inspector to figure it out. Did I mention I’m not a fan of cleaning around the bowl – or re-caulking for that matter? They are also not the same thickness in wall diameter. Honestly, it makes me nervous. Push the seal ends of the connectors into the toilet bowl. I don;t want to have to take out the wall. In reading the Gerberit website, they specifically state it can be done for a new build or renovation with 2×4 framing. I’m disappointed that this has caused so much angst etc with us and the builders. Any insight is appreciated! Prior mounting the unit, adjust the frame for your desired future toilet bowl and seat height. (image from Geberit – used with permission). Finished. Thanks for the kind words and thanks for using the site. Like the previous blogger- we are at the Jersey Shore and I have showed more than 10 plumbers this – no one understands how to do this. Your email address will not be published. Besides, installation needs a professional which will require some more bucks from your pocket. Regarding the in-wall carrier tank, it is true that accessibility is an issue and a potential maintenance concern. You can also install the standard discharge pipe at up to a 45 degree angle left or right without the above horizontal discharge pipes. I don’t know why they seem to hate these things but every one that I have talked to has tried to talk me out of it. 8. I pass this line through the floor plate, along the left rear of the wall cavity to accommodate the front-mounted toilet carrier frame. Find the supplied plumbing connector set with inlet and outlet seals and connection hardware. It’s also possible the pipe was not affixed to the Geberit frame. Well, recently I did and a shiny new Toto Aquia now awaits to be mounted onto the fully installed Geberit 2×4 wall carrier. Did you perform a trial run on the tank to make sure there weren’t any leaks before closing up the walls? With the 2×4 wall, you will have to cut out the entire 2×4 floor plate to pass the 3″ waste plumbing. Wow! I am traveling but will reply with a more substantial reply to your questions in a few days. I took few precautions and I dont face any issues now. Another option is the slim, against the wall Monolith tanks by Geberit. Before we can hang the toilet, we need to insert the plumbing adaptors and seals that will attach to the toilet bowl. With the straight pipe replacement I am able to eliminate 2 of those 90’s! Fixture for wall-mounted toilet or bidet A fixture for a wall-mounted toilet and a wall-mounted bidet makes it simple for you to carry out a neat, secure installation without having to reinforce the walls. The bathroom sink is from the “Happy D” line of console sinks by Duravit. If it can be done on an angle, what would the maximum be? If the holes are too small, you can crack the framing. They’re ideal for small bathrooms because they occupy zero floor space and they make the room look more spacious overall. Did you have to use multiple layers of drywall, or did it work fine over standard 1/2″ drywall? Add 1/8″ to get 3 1/8″. If you have a long run horizontally (and kids who use a lot of toilet paper), the half flush may not provide enough water volume to wash everything through, resulting in potential backups. 3.13330006599426 star rating Reviews / Write a Review. -Ease of cleaning. A seal in the Geberit kit goes on the toilet end of the inlet pipe making it seal nicely with the standard 55mm water inlet. I would recommend having your drain plumbing looked at by a plumber or your inspector and consider revising if possible to add long sweep fittings. Where did you get your sink and legs hardware that support the sink? With the cover frame installed, insert the flush control push rods into the access hole in the cam lever unit. I would like my with a seat of height of 15.5″-16″, however should I be concerned with this Amazon review? HI Gary – Not sure if my first message went through. how can be connect vent with wall hung water closet. One of worse examples of the confusion I’m talking about is Toto video on this subject: https://www.youtube.com/watch?v=q0T6hTTvpgA&t=588s. How do you get to the tank to fix things? This is an easy / common fix to install a standard water pressure tank for $40 – $50 and reverse flow preventer which makes up for the missing GPM. They are meant for applications where the static water pressure is at least 75 PSI and 18 – 20 GPM and there is no tank. I based much of the new design for both bathrooms around keeping the 3″ waste pipes in roughly the same positions. But, let’s say, again just for future safety when we can forget to reinstall the foam after toilet removal and re-installation, instead of making the pipes shorter by 3mm, they can be shortened by 1-2mm. If you mount the wall carrier on an inside wall, you can access the unit much more easily if needed. The carrier I was looking for was only $150 and had no tank option. Any advises will be appreciated..Thank you. In my case, I stubbed out the waste lines to the proper height, then capped with Fernco caps so I could fill the DWV system for testing. The extra framing feels very sturdy — we’ve been using the toilet for a couple of months and it really doesn’t budge. Typically, wood framing will require lag bolts at the base and standard bolts with nuts at the sides (and top if using). I’ll post a pic of the venting around the carrier on the second floor and possibly a pic of the diagram if I can find it. Great site with lots of helpful information. Any feedback is much appreciated, thanks! It may be necessary to use a thin strip of hardwood, plywood, or something similar to eliminate any gap. Next, install the black cover frame using the locking key pins located at the sides of the cover. Our unit, which I installed (as above), with a toto toilet has been the best toilet I have ever owned/used. Hi Gary, We are building a house at the Jersey Shore and I have always wanted wall-mounted toliets. However, once this distance is transferred to the pipe end, at 9:33, although the voice says that 3mm should be added they are subtracted and the pipe is cut at 120mm, leaving it at least 3mm too long (probably much more due to very rough measuring technique). I would have it fixed now. This article will walk you through the installation of  a residential Geberit in-wall toilet tank and frame system with a TOTO wall-mounted toilet bowl. thank you! Some control rods are sized and colored differently for each flush actuator (check with your install literature). Each wall mounted toilet tank frame has specific stud spacing requirements. Even though I’m not installing it myself, my contractor is doing it – I have a question about being able to have the toilet right against the porcelain wall tiles without caulk/grout. The only visible thing is the bowl. I put a level where the bolts hold the toilet unit and it was not leveled. Then connect the discharge of this fitting to the stubbed out 3″ PVC waste line using the supplied hubless connector. Is it pretty efficient at flushing solid waste even set to the 0.9 or 1.28 flush rate? Thanks Dennis. 7. Just received notification from amazon the my toto & Geberit 111.728.00 was shipped today. It does look nice but give me a standard toilet and tank anytime. The in and out plumbing connections of the Geberit unit must match the height of the in and out openings of the Nameek toilet once it is mounted on the finished floor. I do use both flush buttons. Once level, tighten the mounting nuts and cap with the supplied plastic covers. The Geberit unit allows for seat height adjustments of 15″ – 19″. With our cabin bathroom remodel, we were looking for ways to improve the usability of the small 8′ x 5′ bathroom and decided moving the toilet off the floor and on the wall would open the room and save valuable floor space. I’m now uncomfortable starting until the unit comes in. After installing the finished wall in the guest bathroom and mounting the toilet bowl, I discovered a gap between the back of the drywall and the face of the tank frame. As for the carrier I built my own simply out of frustration trying to find a wall mount carrier that was NOT $500+ and was NOT meant to have a tank in it. The flush inlet (smaller) connector should fit inside the toilet flush opening, and the waste outlet (larger) connector should fit over the toilet waste outlet. Almost any problem that you could have from not using the carrier would be a total mess and likely end up costing you much more in the long run. Too much at stake. I’m thinking easier to clean. Required fields are marked *. Mark both connectors at the level of the wall face with the marker. The unit is built from heavy duty steel tubing and it would be hard to replicate the support provided by the unit. As you point out, the tank is vulnerable too. Designed to maximize water savings, Zurn EcoVantage 1.1 gpf wall hung high efficiency toilet systems provide 31% water consumption savings over traditional 1.6 gpf systems. My main concern is long-term maintenance. TWO PEOPLE ARE RECOMMENDED FOR HANDLING TO AVOID BREAKAGE AND POSSIBLE INJURY! I am on a slab which I understand can complicate the installation. They must end up taking more time than the standard so the plumbers get sloppy. The unit is 23 1/2″ wide. Then pass the valve into the carrier through the access hole (remove the cap first) at the top left of the unit. I bought a GROHE toilet but now the problem is it does not have the bracket that I see on all the youtube videos, now am worried if they did not give me all the components when they were selling this toilet to me. You mentioned that you installed yours with seat height of 17″. 2) Add 1/8″ to this measured distance. Joist depth and spacing, underfloor access, and other framing details can be major constraints if you need to reroute these large pipes. 3. This height maybe not ideal for children, but ours seems just right at 17″. Toilet Tank - Rigid Supply Line Installation Veil™ Wall-Hung Toilet Cast Iron Waste Pipe Connection Weight/Load Bearing Limit for Kohler Toilets, Toilet Seats and Lavatories PVC d/w/v to PVC or PVC d/w/v to cast iron, etc). In larger commercial buildings with lots of toilets, they don’t use these either. I’m remodeling a second floor bathroom to include a new shower. I like the looks of the Toto Aquia – very sleek. With the walls and floors of the bathroom open for our renovation, it was easy for us to add the exact plumbing we needed for the unit. Lubricate the porcelain connection ends at the back of the toilet. Don’t measure from the base molding! If using an elastomeric sealant (like Lexel), working very quickly to smooth, as this product sets up very quickly and has a very short working time before the surface becomes tacky and difficult to smooth. Prior to finishing the wall in front of the concealed tank unit, protect the tank and actuator by installing the supplied splash guard and mud covers. It saves a lot of space in a small bathroom. Hi, Thanks for the valuable comments. The bathrooms are also back to back. It’s important to know that the diameter of the water inlet pipe from the Geberit carrier to the toilet is 45mm. My experience with the Geberit wall unit has been nothing but positive, although I haven’t had to contact their customer service. It’s yours”. Remove both of the connectors. Pic of continuation of the venting on the second floor. At 9:27, the video clearly shows the measured distance of 123mm. Be sure to take this into account when planning the locations of toilets and anything else in the bathroom. Jack: I am interested in your approach. It’s the same Nick who contacted you almost 3 years ago but never really found time to go ahead with this project. Let’s see – the goal is to get exact final length of these two pipes and the measuring procedure described in all the manuals is more or less clear. In addition, there may be issues with access to the rubber gaskets used to seal the carrier and toilet bowl connections. It is especially important to mount the tank frame precisely flush with the face of the framing members. Look a few replies above for a venting example with pics. This unit is designed for 2″x4″ framed walls, but requires a wider, 23 1/2″ stud spread to make room for the water tank in this 2×4 “shallow” unit. Cut the wall? I’ve gotten the standard answer, “We will have our engineers look at this”. 3.8 out of 5 stars 13. Open the area of your bathroom wall where you would like to install your wall mounted toilet. The most difficult aspect of wall mounted toilet installation is accommodating 3″ waste pipes. All of the area below the actuator is drywall that can be easily removed. The VorMax unparelleled scrubbing action circulates water around the bowl from top to bottom, leaving it twice as clean as a conventional toilet while using a … Are the in-wall tanks really worth it?

The C-h Bond In Propane Is, Sign Language For Money, University Of Sydney Quadrangle History, 14 Count Aida Cloth How Many Threads, Alpha Gamma Delta Purdue, Jedward Net Worth,